WEX40-24V-08 (with blend)
Housing WEX40-220V-03 is designed to protect CCTV cameras with fixed or vario lens or zoom lens against adverse environmental effects in highly explosive and fire hazardous areas both inside and outside the premises.
Supply set includes the pneumatic blend worked out in order to prevent the observation glass from pollution by creating an air barrier in front of the glass that doesn’t let dust and dirt accumulate.
Explosion protection certification: 1ExdIICT6X.
WEX40_24V_08_____50926bccc907b.gif
Description
Housing WEX40-24V-08 is designed to protect CCTV cameras with fixed or vario lens or zoom lens against adverse environmental effects in highly explosive and fire hazardous areas both inside and outside the premises.
Supply set includes the pneumatic blend worked out in order to prevent the observation glass from pollution by creating an air barrier in front of the glass that doesn’t let dust and dirt accumulate. Explosion protection certification: 1ExdIICT6X.
Type: |
Special purpose housings |
Efficient useful volume, mm: |
Ø105Х240 |
Series: |
EXPLOSION PROOF |
Additional device for video signal transmission, processing and lightning protection: |
Lightning-arrester and protection against high-voltage impulse interferences |
Operational temperature, degrees Centigrade: |
–60..+50 |
Input voltage to the Housing, V: |
24 AC |
Voltage to be supplied to the TV camera, V: |
9 DC, 12 DC, 24 AC |
Function Features Environmental parameters Geometrical parameters Constructive parameters Electrical parameters Additional information {reg} {reg}Similar models
Function
Housing WEX40-24V-08 is designed to protect CCTV cameras with fixed or vario lens or zoom lens against adverse environmental effects in highly explosive and fire hazardous areas both inside and outside the premises.
Supply set includes the pneumatic blend worked out in order to prevent the observation glass from pollution by creating an air barrier in front of the glass that doesn’t let dust and dirt accumulate.
Type of explosion protection – explosion-proof casing.
Explosion protection certification: 1ExdIICT6X
Conditions of Use
The housing is designed for use in explosive areas both inside and outside premises in which flammable dust, fume and gas mixtures which come under spontaneous ignition temperature group T6 (GOST R 51330.0-99) are (may be) present.
The climate factor standard for use in working conditions according to GOST 15150-69 is for climate version Moderate Cold 1.5, but it is also of the standard for being kept in a corrosive atmosphere, and for marine (III) and coastal industrial (IV) atmospheres.
For use in non-working conditions (transport, storage, to be turned on after a period of disuse) the lowest temperature standard should not be lower than minus 30ºС. According to operational temperature of the environment the housing comes under special electrical apparatus category (GOST R 51330.0-99).
Features
- The type of explosion protection used is an explosion-proof casing (“d” GOST R 51330.1-99). Explosion protection is achieved through enclosure of the camera and all the electronic parts within the explosion-proof casing, which contains the pressure of an internal explosion and prevents the explosion from passing on to the surrounding environment.
- The built-in power supply produces a universal voltage range for cameras and provides galvanic power supply decoupling.
- For the purpose of creating the favorable temperature conditions for the camera to function, the housing is equipped with a triple heating system. The heating system includes a unit of heaters which directly maintain the temperature of the camera body, a dual-mode screen heater and a high-powered mounting plate heater.
- The housing control unit carries out the trouble-free procedure of switching on the camera (the power supply is fed to the camera only after preliminary warming-up).
- The camera body heater (6 W) is controlled by an electronic sensor.
- The mounting plate heater (20 W) and the dual-mode screen heater (4.5/13.5 W) are controlled by a bimetal thermorelay.
- A wall bracket with two degrees of freedom ensures the vertical mounting of the housing and the choice of scan direction of the camera (search for objects) to a wide range of angles.
- Input voltage: 24V AC.
- The exterior elements of the housing construction are made out of corrosion-resistant materials.
- The built-in lightning-arrester and protection against high-voltage impulse interferences.
Environmental parameters
Tested operating range of ambient temperature |
–60°С..+50°С |
Class of protection against environmental impacts |
IP66 (complete dust protection; protection against water jets from any direction) |
Geometrical parameters
Overall dimensions and usable volume:
Constructive parameters
Diameter of cables for connection of housing |
3.1 ÷ 13.9 mm |
Weight of assembled housing |
15 kg |
Maximum load at bracket |
60 kg with safety factor 2,6 |
Material |
stainless steel 12Х18Н10Т (AISI 321Ti) |
Glass |
shockproof, multilayer |
Fastening parts |
stainless steel |
Material of sealing gaskets |
warm-, cold-, acid-, caustic-resistant rubber |
Material of cable glands |
explosion proof brass |
Technical characteristics of defense pneumatic blend
- inlet fitting for compressed air supply - 1/2"
- air expenditure under pressure
- 1 BAR - 1,83 l/s
- 1,5 BAR - 2,75 l/s
- 2 BAR - 3,67 l/s
- 2,5 BAR - 4,58 l/s
- dimensions - Ø164х44 mm
- made of 12Х18Н10 stainless steel
Electrical parameters
Maximum power, consumed by housing (including TV-camera) |
55W |
Maximum current, consumed by housing (including TV-camera) |
2,25A (24V AC) |
TV-camera heater |
power |
6W |
Mounting plate heater |
power |
20W |
2 steps glass heater |
power |
4,5W/13,5W |
TV-camera power supply |
input voltage |
24V AC±10% |
output voltage (one of specified voltages shall be selected by user) |
24V AC±10% (400 mA max); 12V DC±10% (400 mA max); 9V DC±10% (400 mA max); |
Galvanic power supply decoupling |
transformer |
Lightning-arrester specifications:
Frequency band |
50Hz÷7MHz |
Decrease of frequency characteristic at 6MHz |
3db |
Maximum level of input signal |
10V |
Minimal voltage necessary for operation of protection system |
11V |
Response time |
15ns |
Maximum impulse current of protection |
at voltage from 11 to 90V |
200А |
at voltage above 90V |
10000А |
Operating temperature range |
-40ºC..+50ºC |
Ранее используемые типы кабеля:
Тип и длина (до 10 м.) кабеля питания |
Тип и длина (до 10 м.) кабеля видеосигнала |
Тип и длина (до 10 м.) кабеля управления |
NYM 3х1,5 |
Belden 9116 (TV, SAT, CATV 6) |
Hyperline UTP4-C5E-SOLID-GY |
ВБбШнг 3х1,5 |
CAVEL DG 113 |
Hyperline UTP4-C5E-SOLID-OUTDOOR-40 |
ВВГ 3х1,5 |
SAT 50M |
Teldor 8391304109 FTP Cat5e 4x2x24AWG |
ВВГнг 2х1,5 |
RG59/U |
Герда КВКнг-LS 2х2х1,0 |
ВВГнг-LS 2х1,5 |
РК75-4-11 |
КВПВП 5e 2х2х0,52 |
ВВГнг 3х1,5 |
РК75-4-15 |
КВПВП 5e 4х2х0,52 |
ВВГнг 3х2,5 |
РК75-4-351ф |
КВПЭф5e 4х2х0,052 (Parlan™ F/UTP4-Cat5e) |
ВВГнг-LS 3х1,5 |
|
КИПвЭВнг-LS 2х2х0,78 |
Герда КВКнг-LS 2х2х1,0 |
|
КИПЭВнг(А)-LS 2х2х0,60 |
КВБбШв 4х1,0 |
|
КПСВВнг(А)-LS 1x2x1,0 |
КВБбШнг 4х1,0 |
|
ЭКС-ГВПВЭ-5e 4х2х0,51 |
КВБбШнг 4х1,5 |
|
ЭКС-ГВПВ-5e 4х2х0,51 внешний |
КВВГнг-LS 4х1,5 |
|
|
КВВГнг-LS 4х2,5 |
|
|
ПВС 3х0,75 |
|
|
ПВС 3х1,5 |
|
|
ПВС 3х1,5 |
|
|
Также Вы можете заказать свой тип кабеля
Additional information
Supply set:
Housing with connected heaters, temperature detectors, installed control blocks and power supply and transmitter at twisted pair
with lightning arrester |
1 |
Pneumatic blend |
1 |
Sun shield |
1 |
Cable glands for connection of power supply and video signal outlet |
type and number indicate by order |
Power supply cable |
type and length indicate by order |
Video signal cable |
type and length indicate by order |
Control cable |
type and length indicate by order |
Isolation bush |
1 |
Isolation gasket |
1 |
Adjusting gaskets |
4 |
Screws of different length for fastening of TV-camera |
3 |
Screw for fixing of heaters block with temperature detector |
1 |
Wall bracket |
1 |
Silica gel |
2 |
Operating and assembling manual – Housing with TV-camera |
1 |
Warranty coupon |
1 |
All used engineering solutions are patented |
№ 13437, № 20599 |
Certificate |
ROSS RU.MLO4 V00499 |
{reg} {reg}